Parameter read full, Plc block transfer emulation instruction data – Rockwell Automation 1203 Serial Communications Module Series B User Manual

Page 56

Advertising
background image

5–8

1203–5.5 September 1995

The Parameter Read Full function provides all known attributes for
the parameters requested. This information includes the parameter’s
current value, descriptor, multiply and divide value, base value,
offset value, text string, group element reference, minimum value,
maximum value, default value, and unit text string.

PLC Block Transfer Emulation Instruction Data

PLC request instruction length: 3 words
Drive response instruction length: 20 words

Data

Word 1

PLC Decimal Value

768

Message Structure

Data

Word 2

Data

Word 3

PLC Request

Header Word 1

Header Word 2

Data Word 3

Parameter Value

Message Length

Descriptor

Multiply Value

Drive Response

Parameter Number

3

(See Drive List)

or Status Word

Data

Word 4

Data

Word 5

Divide Value

Base Value

Data

Word 6

Data

Word 7

Offset Value

Parameter Text

Char 2

Char 1

Data

Word 8

Parameter Text

Char 4

Char 3

Data

Word 9

Parameter Text

Char 6

Char 5

Data

Word 10

Parameter Text

Char 8

Char 7

Data

Word 11

Parameter Text

Char 10

Char 9

Data

Word 12

Parameter Text

Char 12

Char 11

Data

Word 13

Parameter Text

Char 14

Char 13

Data

Word 14

Parameter Text

Char 16

Char 15

Parameter Read Full

Advertising