Safety precautions, Quick start, Safety precautions -6 quick start -6 – Rockwell Automation 1203-USB Converter User Manual

Page 16

Advertising
background image

1-6

Getting Started

PowerFlex 1203-USB Converter User Manual

Publication DRIVES-UM001D-EN-P

Safety Precautions

Please read the following safety precautions carefully.

Quick Start

This section is provided to help experienced users quickly start using the
1203-USB converter. If you are unsure how to complete a step, refer to the
referenced chapter.

!

ATTENTION: Risk of injury or equipment damage exists. Only
personnel familiar with drive and power products and the
associated machinery should plan or implement the installation,
startup, configuration, and subsequent maintenance of the product
using the converter. Failure to comply may result in injury and/or
equipment damage.

!

ATTENTION: Risk of injury or equipment damage exists. If the
converter is transmitting control I/O to the drive (indicated by a
steady green Diamond status indicator), the drive may fault when
you remove or reset the converter. Determine how your drive will
respond before removing or resetting a connected converter.

Step Action

See

1

Review the safety precautions for the converter.

Throughout this manual

2

Install the converter.

When used with DPI drives or SCANport drives:
a. Connect the 1203-USB converter to the drive with a

20-HIM-H10 cable (see

Figure 1.1

).

b. Connect the 1203-USB converter to a computer with a USB

cable.
Make sure that power has been applied to the drive.

When used with DSI drives:
a. Connect the 1203-USB converter to the PowerFlex drive

with a 22-HIM-H10 cable, or to the Kinetix 3 drive with a

2090-CCMUSDS-48AA0x cable (see

Figure 1.2

).

b. Connect the 1203-USB converter to a computer with a USB

cable.
Make sure that power has been applied to the drive.

Chapter 2

,

Installing the

Converter

3

Install the 1203-USB driver and USB serial port driver.

Installing the USB Drivers on

page 2-4

4

Configure the converter for your application.

Use one of the following tools to configure parameters in the

converter:
• Connected Components Workbench software, version 1.02

or later

• DriveExplorer software, version 4.04 or later
• DriveExecutive software, version 1.01 or later
• Terminal emulation software, such as HyperTerminal

Chapter 3

,

Configuring the

Converter

, or

Appendix C

,

Use with

DriveExplorer Software

, or

Appendix D

,

Use with

DriveExecutive Software

, or

Appendix E

,

Use with

HyperTerminal Software