Use with HyperTerminal Software

PowerFlex 1203-USB Converter User Manual

Publication DRIVES-UM001D-EN-P

Navigating with Terminal Emulation Software

Resetting the Converter

Changes to settings of some 1203-USB converter parameters require that
you reset the converter before the new settings take effect. You can reset the
converter by cycling power to the drive or by using converter Parameter 02
- [Reset Module]
.

Set converter Parameter 02 - [Reset Module] to ‘1’ (Reset Module).

The following HyperTerminal workspace is used to reset the converter.

When you enter ‘1’ (Reset Module), the converter will be immediately
reset. When you enter ‘2’ (Set Defaults), the converter will set all converter
parameters to their factory-default values. After performing a Set Defaults,
you must enter ‘1’ (Reset Module) or power cycle the drive so that the new
values take effect. Thereafter, this parameter will be restored to a value of
‘0’ (Ready).

Key

Function
In the main menu, keys 1…3 select a menu option.
In the parameter screen, keys 0…9 enter a value.
Display the main menu or abort changes to a parameter.

Scroll through parameters or events.

Scroll through the values for a parameter.

Save a value for a parameter.

0

9

Esc

or

or

Enter

!

ATTENTION: Risk of injury or equipment damage exists. If the
converter is transmitting control I/O to the drive (indicated by a
solid green diamond LED), the drive may fault when you remove
or reset the converter. Determine how your drive will respond
before removing or resetting a connected converter.

Press the UP ARROW or DOWN ARROW key to scroll

through the parameter list. Press the LEFT ARROW

or RIGHT ARROW key to modify parameter values.

Press the ENTER key to save a new value.

2> Reset Module = Reset Module

Advertising