Converter Events

Many events in the event queue occur under normal operation. If you
encounter unexpected communication problems, the events may help you or
Allen-Bradley personnel troubleshoot the problem. Converter events can be
viewed with Connected Components Workbench software, version 1.02 or
later.

Event Codes for DPI Drives

Code Events

Description

1

No Event

No event present in the event queue.

2

DPI Bus Off Flt

A bus-off condition was detected on DPI. This event may be caused by

loose or broken cables, or by noise.

3

Ping Time Flt

A ping message was not received on DPI within the specified time.

4

Port ID Flt

The converter is not connected to a correct port on a DPI drive.

5

Port Change Flt

The DPI port changed.

6

Host Sent Reset

The DPI drive issued this because it was reset.

7

EEPROM Sum Flt

The EEPROM in the converter is corrupt.

8

Online @ 125kbps

The converter and DPI drive are communicating at 125kbps.

9

Online @ 500kbps

The converter and DPI drive are communicating at 500kbps.

10

Bad Host Flt

11

Dup Port Flt

Another peripheral with the same port number is already in use.

12

Type 0 Login

The converter has logged in for type 0 control.

13

Type 0 Time Flt

The converter has not received a type 0 status message within the

specified time.

14

DL Login

15

DL Reject Flt

16

DL Time Flt

17

Reserved

18

Control Disabled

The converter has sent a ‘Soft Control Disable’ command to the DPI

drive.

19

Control Enabled

The converter has sent a ‘Soft Control Enable’ command to the DPI

drive.

20

PCCC I/O Time Flt The converter has not received a PCCC Control message for longer

than the specified PCCC Control Time-out.

21

Normal Startup

The converter initially powered up or was reset.

22

Message Timeout

The DPI drive did not respond to a message request. Verify that cabling

is correct.

23

Ping in Message

An unexpected ping was received.

24

DPI Fault Msg

The drive entered a faulted state.

25

DPI Fault Clear

A DPI drive has issued a fault clear message.

26

Manual Reset