Mount the Motor Coil

Use M4 x 0.7 screws with a length that extends through the carriage
mounting surface by minimum of 5 mm (0.197 in.), but not more than
7 mm (0.276 in.).

Follow these steps to mount the motor coil.

1. Clean and remove burrs from the coil mounting surface.

2. Attach the motor coil to the carriage using M4 x 0.7 screw.

Lightly tighten the screws.

3. Slide the assembly on to the bearings.