Mounting and wiring two identical coils in tandem, Cables exit to the right – Rockwell Automation LDL Ironless Linear Servo Motors User Manual

Page 35

Advertising
background image

Publication LDL-UM001A-EN-P - March 2009

35

Wiring the LDL-Series Linear Motor Chapter 5

Mounting and Wiring Two
Identical Coils in Tandem

This type of installation requires custom motor database file which is
available upon request. Contact Application Engineering at
631.344.6600 to request this file.

The following tables and diagrams show the wiring and spacing for

two identical coils mechanically top mounted

(1)

to the same plate and

driven by one amplifier. There are three configurations shown here
for mounting motors in tandem: power and encoder cables exiting on
the right, the center, and on opposite ends.

Cables Exit to the Right

If mounting coils in tandem, such that the power cables exit both of
the coils on right side as shown, use the following table to find
mounting distance and phase wiring.

(1) Contact Application Engineering (631.344.6600) for side mounting of the coils.

ATTENTION

Coils must have identical part numbers. Using mis-matched
coils will cause a hazardous condition resulting in damage to
the equipment and a possible fire.

L1

Coil #1 is the master

Coil #1

Coil #2

Hall Effect

Phase Wiring for Right Exit Power Cables

L1
mm (in.)

Coil # 1
Master

(1)

Coil # 2
Slave

(2)

Amplifier
Phase

80 (3.15)

Red

White

U

White

Black

V

Black

Red

W

120 (4.72)

Red

Black

U

White

Red

V

Black

White

W