Rockwell Automation LDL Ironless Linear Servo Motors User Manual
Page 44
Advertising
44
Publication LDL-UM001A-EN-P - March 2009
Chapter 6 Configure and Start Up the LDL-Series Linear Motor
6. Using the screen image as a reference, configure the parameters
as shown in the Setting column.
RSLogix 5000 Software Version 15.00 and 16.00 TTL Encoder
RSLogix 5000 Software Version 15.00 and 16.00 Sin/Cos Encoder
Parameter
Setting
Comment
Feedback Type
TTL or Sin/Cos
For RSLogix 5000 software,V16
TTL with Hall or Sin/Cos with Hall
For RSLogix 5000 software, V17
Cycles 50
5
µm
encoder
125
2 µm encoder
250 1
µm
encoder
500
0.5 µm encoder
50
20 µm Sin/Cos encoder
(1)
(1) Requires custom database file contact Application Engineering at 631.444.6600.
25
40 µm Sin/Cos encoder
per
Millimeters
–
Interpolation Factor
4
TTL
1024
Sin/Cos