7.0 OPERATOR CONTROLS

The main operator control panel is located at the top

right of the front guard. See Figure 10. The "Control

Panel"(1) is a full color touch sensitive screen. See Quick

Start Instructions for detailed explainations (Page 14).

7.0 Setting Folding Speed

The speed of the fold rolls may be set while the folder is

running! This is done by adjusting the speed control potenti-

ometer located on the top of the front guard (2). Clockwise

rotation speeds the folder up; counter-clockwise rotation

slows the folder down.

7.1 Setting Stacker Belt Speed

An infinite speed range between high and low is set by

turning the speed control potentiometer mounted on the side

of the stacker (3). For shingling purposes use range

2 - 4. Higher speeds may be selected for use as a transfer

table.

7.2 Emergency Stop Button

When an emergency stop button is pressed,

the result is:

Sheet feed - stop

Folder drive - stop

Delivery feed - stop

Pump - stop

The emergency stop button must be pulled to release before

the machine can be restarted. The status indicator will change

to an exclaimation point inside of a red triangle inside a red

circle with a yellow background when the estop is active.

The emergency stop button is found on the right side of the

front guard (4).