8.0 BASIC MACHINE SETUP

8

.1: Units of Measurement

Toggles between metric and english units ( mm or inches).

See Quickstart Instructions page 14.

8.2: Language

This selection specifies the Language. Available choices

are ENGLISH, GERMAN, SPANISH and FRENCH. Use the

Setup Preferences Screen to change languages. See
Quickstart Instructions page 22.

8.3: Hardware and SoftwareVersion

This hardware versions are shown on the serial number

plate. This is located on the inside of the front frame between

pan 1 and pan 2.

The software loaded into each programmable component

is indicated by a label stuck onto each component: PLC, HMI,
and VFD.

9.0 DIAGNOSTICS

The inputs and output of the PLC can be monitored using the

HMI. Access the main screen using one of the orange

buttons with the upward arrow.

From the main screen select the Troubleshooting screen.

Green indicators show "on" states for all inputs X0-X7 and

outputs Y0-Y5. The encoder counts can also be monitored

here. There is also a button to force the solenoid "on."