Baumfolder 714XA User Manual
Page 43
TP10583
PAGE 40
E.) Run the paper stop to it’s home position by rotating the paper stop
lead screw by hand.
F.) Carefully rotate the deflector up so that you may get the calipers or
scale into the pan.
G.) In the center of the fold pan, take a measurement form the edge of the
lower half of the pan to the paper contact surface of the paper stop.
See Figure #9
FRONT SURFACE OF
LOWER HALF PAN
PAPER CONTACT SURFACE
OF PAPER STOP
MEASUREMENT NEEDED
Figure #9
H.) Using half of the measurement determined that the fold was off from
being folded in half in Step #6.C will either be added to or
subtracted from the measurement in Step #6.G.
-If the fold was to long, then half of the measurement taken in Step
#6.C will be subtracted from the measurement in Step #6.G. This
will become the new measurement for the home position of the
paper stop.
-If the fold was to short, then half of the measurement taken in Step
#6.C will be added to the measurement in Step #6.G. This
will become the new measurement for the home position of the
paper stop.