Continuous output formats – Cardinal Industries 225 WEIGHT INDICATOR User Manual

Page 99

Advertising
background image

CONTINUOUS OUTPUT FORMATS

displayed

G = Gross, T = Tare, N = Net

oint

xxxxxx.xxx = Weight

Six digits

Added to string if enabled in setup

ross, N = Net

f zero

SMA

<lf><s><r><n><m><f><xxxxxx.xxx><uuu><cr>

Where:

lf =

Line Feed

s =

Flags

Z= center of Zero, O = Over cap, E = zero Error,
e = weight not currently being

r =

Range

1, 2, 3, ...

n =

Mode

m =

Motion

M = Motion, " "(blank) = no motion

f =

Custom

Custom flag

xxxxxx.xxx = Weight

Six digits with decimal p

uuu =

Units

ton, lb, oz, t, kg, g

cr =

Carriage Return

(hex 0D)


SB-400

<s><xxxxxx><d><uu><m><cc><cr>

Where:

s =

Sign

"-" = negative, " " (blank) = positive

d =

Decimal point

uu =

Units

tn, lb, oz, t, kg, g

m =

Mode

G = G

cc =

Weight Status

OC = over capacity
CZ = center o
MO = motion
ee = weight not currently being displayed

cr =

Carriage Return

(hex 0D)