Horizontal right through top – Carrier DIRECT VENT 4 58HDV User Manual

Page 25

Advertising
background image

25

OF

F

ON

AIR FLOW

3

/

16

(4.8mm) ID Rub-

ber Tube

Trap Connection

“Clamp ears”
Pointed OUT

Preassemble &
insert into furnace

25--24--70b

Single Pressure Switch Detail

Dual Pressure Switch

Tee Trap White PVC
(loose parts bag)

WARNING
Add Cap and Clamp

Drain Tube Black Rubber

1

/

2

(12.7mm) ID & Clamps

EXHAUS

T

Alternate Orientation

Field
Supplied Tee

Cut Here

Drain Tube Corrugated

5

/

8

(15.9mm) ID &

Clamps Cut at straight section

Leave room for clamp

Flexible Tubing Connector

3

/

16

(4.8mm) OD (Loose

Parts Bag)

Plastic Cap
Yellow or black

Vent Drain
& Clamps

INLET

On Some Models
ONLY

Coupling & Clamps
(Optional)

Relief Tube Black Rub-
ber

3

/

16

(4.8mm) ID

Drain Tube Black
Rubber

1

/

2

(12.7mm)

ID & Clamps

Relief Tube Extension
Black Rubber

3

/

16

(4.8mm) ID

Cut to Fit (Loose Parts Bag)

Barbed Coupling

1

/

2

(12.7mm)

OD (Loose Parts Bag)

Representative drawing only, some models may vary in appearance.

Remove KO before
mounting Trap

A07711

Fig. 18 -- Horizontal Right through Top

Horizontal Right through Top

(See Fig. 18)

Disconnect the hoses from the trap assembly, and remove trap and
trap mounting bracket from the blower compartment. Using cover

plate and gasket provided in the loose parts bag, cover the hole
from the burner compartment to the blower compartment and

secure with screws.
Remove knockout from the side of the furnace casing where drain
tube will exit.
Mount the trap externally to the bottom side of the unit using the
two(2) screws provided in the location shown.
Cut the corrugated tube as shown in the illustration above. Connect

the corrugated hose from the transition to the trap.

Secure

connections with clamps.
Connect the black

1

/

2

″ (12.7mm) ID drain tube from the Vent Drain

to the trap. If an extension is required, use the black

1

/

2

″ (12.7mm)

OD barbed coupling and the black

1

/

2

″ (12.7mm) ID drain tube in

the loose parts bag. Cut tube to length. Secure connections with
clamps.

Connect the

3

/

16

″ (4.8mm) ID relief tube to the middle port on the

trap. If an extension is required, use the clear

3

/

16

″ (4.8mm) OD

flexible tubing connector and the black

3

/

16

″ (4.8mm) ID relief tube

in the loose parts bag. Cut tube to length.
Cut an appropriate length of 2″ (50.8mm) PVC pipe, fittings and

extension pipe long enough to exit the cabinet and connect the vent
drain to a standard field supplied 2″ (50.8mm) PVC tee

S

A 2″ (50.8mm) PVC coupling fastened onto the drain tee

Install tee trap into bottom section of tee and glue pipe.
Connect the tee trap and the main drain line exiting the casing as

shown in Fig. 18.
NOTE:

It is recommended that all PVC piping and fitting

connections be fit up and inspected before final cementing. Both
the external trap and the external tee trap must be primed
before operation.
Verify all condensate drain connections are
securely clamped. A coupling and clamps (in loose part bag) may
be installed as shown for future servicing of the vent system.