5. Position furnace or coil cabinet and furnace on subbase so it

aligns between the locating tabs.

Furnace

Plenum

Wood Floor

Installation of
Combustible
Floor Base

A07783

Fig. 49 -- Setting the Subbase

This subbase for combustible floors has been designed so that the
height of the subbase raises the downflow coil off the floor to allow

easy installation of the condensate drain. See Fig. 50

A07784

Fig. 50 -- Condensate Line Raised by Base

CHECKS AND ADJUSTMENTS

NOTE:

Verify the input rate of the furnace.

FIRE OR EXPLOSION HAZARD
Failure to follow this warning could result in personal injury,

death and /or property damage.
Turn OFF gas at shut off before connecting manometer.

!

WARNING

Startup

NOTE: Refer to the start--up procedures in the “User’s Information
Manual
” or to the “Operating Instructions Label” on the furnace.

ELECTRICAL OPERATION HAZARD
Failure to follow this warning could result in personal injury,

death, and/or property damage.
If any sparks, odors or unusual noises occur, immediately shut

OFF power to the furnace.

Check for wiring errors or

obstruction to blower.

!

WARNING

Gas Supply Pressure

Gas supply pressure should be within minimum and maximum
values listed on rating plate. Pressures are usually set by gas

suppliers.

Manifold Gas Pressure Adjustments

(High and Low Heat)

NOTE: Make adjustment to manifold pressure with burners

operating.

FIRE OR EXPLOSION HAZARD
Failure to follow this warning could result in personal injury,

death and /or property damage.
Turn OFF gas at shut off before connecting manometer.

!

WARNING

58H

D