Thermostat Wiring Guide

1.

These diagrams are for reference. See thermostat

wiring

instructions

for

specific

terminal

assignments, connections or operation.

2.

Humidifier/humidistat is optional and not included

with the furnace.

3.

Dehumidify feature requires thermostat with

DEHUM feature or a separate dehumidistat to get

the dehumidification operation. Dehumidistat is

optional and not included with the furnace.

4.

Underlined terminal indicates intended use for

multiple function terminals.

5.

TSIB terminals only available on 58HDV/359BAV

models.

6.

Two--stage Air Conditioning or two--stage Heat

Pump compatible.

7.

W2 furnace operation is from furnace control

algorithm SW1 DIP switch #3 (TT) set to OFF.

Furnace runs in Low Heat for 12 minutes then

switches to High Heat if heating call still exists.

8.

24V HUM terminal on furnace control is used to

power a humidifier (on call for heat and pressure

switch closed) if no HUM thermostat option is

available.

9.

DEHUM provides a 20% reduction in airflow (when

Y1 or Y1 + Y2 is energized) when the furnace

control DEHUM terminal is energized with 24V.

10.

If no DEHUM thermostat option is available, a

dehumidistat that has closed contacts on a call for

dehumidify may be used

11.

O provides a 10% reduction in airflow when Y1 or

Y1 + Y2 is energized and O is NOT energized. (J2

jumper on TSIB must be in HP COMFORT position

to get this function. AC/HP EFFICIENCY position

results in no reduction of airflow for Y1 or Y1 + Y2

calls regardless of O being energized or not.)

12.

For Heat Pump/Furnace systems, refer to Fossil Fuel

Kit or Dual Fuel Thermostat Installation Instructions

for wiring.

NOTE 3, 9, 10

Y

W

G

R

W1

Y/Y2

G

R

C

C

OM

TWO-STAGE or VS

FURNACE

CONTROL

SINGLE-STAGE

AIR CONDITIONER

Y

C

SINGLE-STAGE

THERMOSTAT

W2

24V in

COM

OPTIONAL

HUMIDIFIER

DEHUM

HUM

24V HUM

DEHUM

NO CONNECTION

NO CONNECTION

NOTE 2

NOTE 11

NOTE 7

Y1

O

TSIB

NOTE 5

A07787

Fig. 56 -- HUM and DEHUM Terminal available from Thermostat. Humidifier Wiring Models and Dehumidify Wiring