This command is applicable only in PMUX mode.

3. Add the interface to the second port channel.

INTERFACE PORT-CHANNEL mode

channel-member interface

Example of Moving an Interface to a New Port Channel

The following example shows moving the TenGigabitEthernet 0/8 interface from port channel 4 to port
channel 3.

Dell(conf-if-po-4)#show config

!

interface Port-channel 4

channel-member TenGigabitEthernet 0/8

no shutdown

Dell(conf-if-po-4)#no chann tengi 0/8

Dell(conf-if-po-4)#int port 3

Dell(conf-if-po-3)#channel tengi 0/8

Dell(conf-if-po-3)#sho conf

!

interface Port-channel 3

channel-member TenGigabitEthernet 0/8

shutdown

Dell(conf-if-po-3)#

Configuring the Minimum Oper Up Links in a Port Channel

You can configure the minimum links in a port channel (LAG) that must be in “oper up” status to consider

the port channel to be in “oper up” status.

To set the “oper up” status of your links, use the following command.

• Enter the number of links in a LAG that must be in “oper up” status.

INTERFACE mode

minimum-links number

The default is 1.

Example of Configuring the Minimum Oper Up Links in a Port Channel

Dell#config t

Dell(conf)#int po 128

Dell(conf-if-po-128)#minimum-links 5

Dell(conf-if-po-128)#

Configuring VLAN Tags for Member Interfaces

To configure and verify VLAN tags for individual members of a port channel, perform the following:

1.

Configure VLAN membership on individual ports
INTERFACE mode