Displaying uplink failure detection – Dell PowerEdge FX2/FX2s User Manual

Page 212

Advertising
background image

Displaying Uplink Failure Detection

To display information on the UFD feature, use any of the following commands.

• Display status information on a specified uplink-state group or all groups.

EXEC mode

show uplink-state-group [group-id] [detail]

group-id: The values are 1 to 16.
– detail: displays additional status information on the upstream and downstream interfaces in

each group.

• Display the current status of a port or port-channel interface assigned to an uplink-state group.

EXEC mode

show interfaces interface

interface specifies one of the following interface types:
– 10 Gigabit Ethernet: enter tengigabitethernet slot/port.
– Port channel: enter port-channel {1-128}.

If a downstream interface in an uplink-state group is disabled (Oper Down state) by uplink-state
tracking because an upstream port is down, the message error-disabled[UFD] displays in the output.

• Display the current configuration of all uplink-state groups or a specified group.

EXEC mode or UPLINK-STATE-GROUP mode

(For EXEC mode) show running-config uplink-state-group [group-id]

(For UPLINK-STATE-GROUP mode) show configuration

group-id: The values are from 1 to 16.

Example of Viewing Uplink State Group Status

Dell# show uplink-state-group

Uplink State Group: 1 Status: Enabled, Up

Uplink State Group: 3 Status: Enabled, Up

Uplink State Group: 5 Status: Enabled, Down

Uplink State Group: 6 Status: Enabled, Up

Uplink State Group: 7 Status: Enabled, Up

Uplink State Group: 16 Status: Disabled, Up

Dell# show uplink-state-group 16

Uplink State Group: 16 Status: Disabled, Up

Dell#show uplink-state-group detail

(Up): Interface up (Dwn): Interface down (Dis): Interface disabled

Uplink State Group : 1 Status: Enabled, Up

Defer Timer : 10 sec

Upstream Interfaces : Po 128(Up)

Downstream Interfaces : Te 0/1(Dwn) Te 0/2(Dwn) Te 0/3(Up) Te 0/4(Dwn) Te

0/5(Up)

212

Uplink Failure Detection (UFD)

Advertising