Dell PowerEdge FX2/FX2s User Manual

Page 195

Advertising
background image

Master Switch Fails

• Problem: The master switch fails due to a hardware fault, software crash, or power loss.
• Resolution: A failover procedure begins:

1.

Keep-alive messages from the Aggregator master switch time out after 60 seconds and the switch is

removed from the stack.

2.

The standby switch takes the master role. Data traffic on the new master switch is uninterrupted.

Protocol traffic is managed by the control plane.

3.

A member switch is elected as the new standby. Data traffic on the new standby is uninterrupted.

The control plane prepares for operation in Warm Standby mode.

Stack-Link Flapping Error

Problem/Resolution: Stacked Aggregators monitor their own stack ports and disable any stack port that
flaps five times within 10 seconds. If the stacking ports that flap are on the master or standby, KERN-2-
INT error messages note the units.

To re-enable a downed stacking port, power cycle the stacked switch on which the port is installed.

The following is an example of the stack-link flapping error message.
--------------------------------------MANAGMENT

UNIT-----------------------------------------

Error: Stack Port 49 has flapped 5 times within 10 seconds.Shutting down this stack port now.

Error: Please check the stack cable/module and power-cycle the stack.

10:55:20: %STKUNIT1-M:CP %KERN-2-INT: Error: Stack Port 50 has flapped 5 times

within 10

seconds.Shutting down this stack port now.

10:55:20: %STKUNIT1-M:CP %KERN-2-INT: Error: Please check the stack cable/

module and

power-cycle the stack.

---------------------------------------STANDBY

UNIT------------------------------------------

10:55:18: %STKUNIT1-M:CP %KERN-2-INT: Error: Stack Port 50 has flapped 5 times

within 10

seonds.Shutting down this stack port now.

10:55:18: %STKUNIT1-M:CP %KERN-2-INT: Error: Please check the stack cable/module

and power-cycle the stack.

Master Switch Recovers from Failure

• Problem: The master switch recovers from a failure after a reboot and rejoins the stack as the standby

unit or member unit. Protocol and control plane recovery requires time before the switch is fully

online.

• Resolution: When the entire stack is reloaded, the recovered master switch becomes the master unit

of the stack.

Stack Unit in Card-Problem State Due to Incorrect Dell Networking OS Version

• Problem: A stack unit enters a Card-Problem state because the switch has a different Dell Networking

OS version than the master unit. The switch does not come online as a stack unit.

• Resolution: To restore a stack unit with an incorrect Dell Networking OS version as a member unit,

disconnect the stacking cables on the switch and install the correct Dell Networking OS version. Then

add the switch to the stack as described in

Adding a Stack Unit

. To verify that the problem has been

resolved and the stacked switch is back online, use the show system brief command.

Dell#show system brief

Stack MAC : 00:1e:c9:f1:00:9b

Stacking

195