4. Initialize the port-channel with configurations such as admin up, portmode, and switchport.

Dell#configure

Dell(conf)#int port-channel 128

Dell(conf-if-po-128)#portmode hybrid

Dell(conf-if-po-128)#switchport

5. Configure the tagged VLANs 10 through 15 and untagged VLAN 20 on this port-channel.

Dell(conf-if-po-128)#vlan tagged 10-15

Dell(conf-if-po-128)#

Dell(conf-if-po-128)#vlan untagged 20

6. Show the running configurations on this port-channel.

Dell(conf-if-po-128)#show config

!

interface Port-channel 128

portmode hybrid

switchport

vlan tagged 10-15

vlan untagged 20

shutdown

Dell(conf-if-po-128)#end

Dell#

7. Show the VLAN configurations.

Dell#show vlan

Codes: * - Default VLAN, G - GVRP VLANs, R - Remote Port

Mirroring VLANs, P - Primary, C - Community, I - Isolated

O - Openflow

Q: U - Untagged, T - Tagged

x - Dot1x untagged, X - Dot1x tagged

o - OpenFlow untagged, O - OpenFlow tagged

G - GVRP tagged, M - Vlan-stack, H - VSN tagged

i - Internal untagged, I - Internal tagged, v - VLT

untagged, V - VLT tagged

NUM Status Description Q Ports

* 1 Active U Te 0/3

10 Active T Po128(Te 0/4-5)

T Te 0/1

11 Active T Po128(Te 0/4-5)

12 Active T Po128(Te 0/4-5)

T Te 0/1

13 Active T Po128(Te 0/4-5)

T Te 0/1

14 Active T Po128(Te 0/4-5)

T Te 0/1

15 Active T Po128(Te 0/4-5)

T Te 0/1

20 Active U Po128(Te 0/4-5)

U Te 0/1

Dell#

You can remove the inactive VLANs that have no member ports using the following command:

Dell#configure

Dell(conf)#no interface vlan vlan-id

vlan-id — Inactive VLAN with no member ports

PMUX Mode of the IO Aggregator

235