Show fc switch command example – Dell PowerEdge FX2/FX2s User Manual

Page 265

Advertising
background image

Field

Description

FCF MAC

Fibre Channel forwarder MAC: MAC address of Aggregator with the FCF

interface.

Fabric Intf

Fabric-facing Aggregator with the Fibre Channel port (slot/port) on

which FCoE traffic is transmitted to the specified fabric.

FCoE VLAN

ID of the dedicated VLAN used to transmit FCoE traffic from a server

CNA to a fabric and configured on both the server-facing Aggregator

with the server CNA port.

Fabric Map

Name of the FCoE map containing the FCoE/FC configuration

parameters for the server CNA-fabric connection.

Enode WWPN

Worldwide port name of the server CNA port.

Enode WWNN

Worldwide node name of the server CNA.

FCoE MAC

Fabric-provided MAC address (FPMA). The FPMA consists of the FC-

MAP value in the FCoE map and the FC-ID provided by the fabric after

a successful FLOGI. In the FPMA, the most significant bytes are the FC-

MAP; the least significant bytes are the FC-ID.

FC-ID

FC port ID provided by the fabric.

LoginMethod

Method used by the server CNA to log in to the fabric; for example,

FLOGI or FDISC.

Secs

Number of seconds that the fabric connection is up.

State

Status of the fabric connection: logged in.

show fc switch Command Example

Dell# show fc switch

Switch Mode : NPG

Switch WWN : 10:00:5c:f9:dd:ef:10:c0

Dell#

Table 27. show fc switch Command Description

Field

Description

Switch Mode

Fibre Channel mode of operation of an Aggregator. Default: NPG

(configured as an NPIV proxy gateway).

Switch WWN

Factory-assigned worldwide node (WWN) name of the Aggregator. The

Aggregator WWN name is not user-configurable.

NPIV Proxy Gateway

265