MODEL 207A AND 207A-1

OPERATION MANUAL

Doc. No. 740044
Rev F

SECTION III - INSTALLATION

3.2

WELDING GAS CONNECTIONS

2. (continued)

NOTE

The arc gas line is controlled by a solenoid and flow sensor in the M-207A

and MUST BE connected to the M-207A (not directly to the weld head or

torch).

After installing the hose and fittings loosely by hand, tighten the retaining

nuts slightly with a wrench to insure there are no leaks, but do not over-

tighten. The use of plumbers tape or grease is not recommended.

CAUTION

The M-207A arc gas solenoid valve is rated at 50 PSI (345 KPa) maximum

pressure, DO NOT EXCEED THIS RATING.


3. The other 10’ (3 m) hose is intended for I.D. PURGE GAS INPUT and its

connection to and through the M-207A is optional. It is supplied with fittings

to connect from the gas source regulator/flowmeter to the PURGE GAS

input bulkhead fitting on the M-207A.


The M-207A does not supply a solenoid for control of I.D. PURGE GAS.

The line feeds straight through to the output quick-disconnect. If the output

hose is plugged in, gas will flow at all times. This feature is best for bench-

type weld development but not normally used for field I.D. purging of long

lengths of tube.


If you wish to use this option, install the hose and fittings loosely by hand,

tighten the retaining nuts slightly with a wrench to insure there are no leaks,

but do not over-tighten. The use of plumbers tape or grease is not

recommended (see figure 4).


4. The 25 foot (7.6 m) hose is intended to supply the I.D. purge from the M-

207A to the weld. One end has a quick-disconnect on it that mates with the

PURGE GAS output bulkhead fitting on the M-207A. If used, the quick-

disconnect provides a convenient method for starting or stopping the flow of

I.D. purge gas. If you wish to use this option, insert the male quick-

disconnect of the hose into the M-207A connector labeled PURGE OUTPUT
(see Figure 2 and 4).