MODEL 207A AND 207A-1

OPERATION MANUAL

Doc. No. 740044
Rev F


SECTION V - OPERATION

5.1

INITIAL POWER ON/STATUS SCREEN

4. (continued)

NOTE

If the input power is too low it is possible for the screens not to turn on, or to

be scrambled or get a fault screen indicating a LVPS fault. If these conditions

occur recycle CB1. If they continue to occur check the input power and the

power setup of the M-207A

UPPER SCREEN

TO WELD PRESS LIB

TO PROGRAM PRESS PRO

SYS HOURS - 00000.0 ARC HOURS - 00000.0

LOWER SCREEN

TEMP-OK

INPUTAC-OK

GAS-OK

LVPS-OK

COOL-OK

SENSOR 1-OK

2-OK

3-OK

Actual hours will appear where the above shows 0. COOL, GAS OR

SENSOR 1, 2, 3 may indicate FLT where OK appears. This is considered

normal at power-up.

5.2

USE OF NEXT/PREV SCREENS/LEVELS

Weld schedules contain more data than can be shown at one time. To display this

data the NEXT/PREV SCREEN keys and NEXT/PREV LEVEL keys must be

used. These keys are located at the corners of the lower display. When there is

more data on another screen or level, a flashing * will appear in the appropriate

corner (s) to indicate that more information is available.

Screen/Level keys are used in selection of a weld schedule and all weld schedules

use 4 basic screens that appear in the following order:

1. PROMPT SCREEN - Appears when a weld schedule is called up from

memory.

2. LEVEL 01 AMPS - TIME - PULSE = Displays the value of AMPS, LEVEL

TIME and PULSE TIMES for LEVEL 1.

3. LEVEL 01 RPM - MODES = Displays the value of ROTATION RPM,

PULSE MODE and TRAVEL MODE for LEVEL 1.

4. PURGE - SLOPE - ROT DELAY = Displays the time for PREPURGE,

POSTPURGE, UPSLOPE, DOWNSLOPE and ROTATION START

DELAY.

Pressing the NEXT SCREEN key will advance the display in the above order.

When viewing screen 2, 3 or 4 (above) pressing the PREV SCREEN key will

reverse the order.