Arc Machines 207 User Manual

Page 74

Advertising
background image

MODEL 207A AND 207A-1

OPERATION MANUAL

Doc. No. 740044
Rev F

SECTION VIII - OPTIONS

8.2

M-207-RP REMOTE PENDANT


2. Operation (continued)


1. The following functions and features are provided by the Remote Pendant:


1. Sequence Start key

2. Sequence Stop key

3. All Stop key

4. Rotation jog CW key

5. Rotation jog CCW key

6. Weld/Test mode key

7. Manual Purge key

8. Print key

9. 8 character digital status display

10. Weld # key

11. Amps Up key

12. Amps Down key


2. Items 1 to 8 above are duplicates of keys contained on the M-207A panel.

They work exactly the same as the keys on the panel. When the RP is

connected these keys and the identical ones on the M-207A panel are active

at the same times. Pressing either key will perform the function desired.

For further information about the use of these keys see section IV and

section V of this manual.


3. The 8-character digital display is used to indicate to the operator what

particular mode or area of a weld schedule the system is in.


When the M-207A is first turned on the RP display will say NO SEQ. This

indicates to the operator that no weld schedule has been selected. When a

schedule is selected the display will show 001 TEST. This indicates the

weld schedule number selected (001) and the system is in TEST mode. It

could indicate WELD or FLT depending on the system status.


When the weld sequence is started the display will indicate progression

through PREPURGE, UPSLOPE, LVL 01 (etc.), DOWNSLOPE and then

POSTPURGE.





8.4

Advertising