MODEL 207A AND 207A-1

OPERATION MANUAL

Doc. No. 740044
Rev F


SECTION V - OPERATION

5.8

AUTO ROTATION CALIBRATION


7. For operation on other systems and MANUAL calibration all AMI weld heads

have a Calibration Potentiometer. An exact setting of this POT is not required

for AUTO CAL but if it is set near one end the system may not be able to

accurately calibrate. If this occurs the following screens will appear:

WELD HEAD POT OUT OF AUTO CAL RANGE

PRESS C TO ABORT AUTO CAL

WELD HEAD TRAVEL SPEED TOO SLOW
TURN POT CCW PRESS ENTER TO RECALIBRATE
CW

Before actually turning the POT look again at the MAX RPM of the head and

make sure it was the one you selected in step 2. Selecting the wrong MAX

RPM will make this screen appear. If it was selected correctly adjust the POT

IN THE DIRECTION INDICATED AND PRESS enter again to repeat the

calibration.


5.9

MANUAL ROTATION CALIBRATION


For Weld Heads other than M-9 or M-96 it will be necessary to MANUALLY

calibrate them. If a user does a lot of weld head changes between systems he may

also choose to MANUALLY calibrate his M-9 weld heads as well. Use the

following procedure to manually calibrate rotation speed.


1. To use the MANUAL calibration function press the SET UP key. This can be

done from the STATUS screen or a WELD SCHEDULE screen. Then press

the F key under HEAD CAL and the following screen will appear:

AUTO TRAVEL SPEED CALIBRATION

WELD HEAD SELECTION MENU

SELECT MAX. RPM (STAMPED ON HEAD TAG)
20.0 2.0 OTHER MANUAL