MODEL 207A AND 207A-1

OPERATION MANUAL

Doc. No. 740044
Rev F


SECTION VIII - OPTIONS

8.1

M227/207-CW & M207-CW

COOLING UNIT SPECIFICATIONS/INSTALLATION


5. Operation -


2. Both M227/207-CW & M207-CW contain flow sensors. Any time the CW

unit is turned ON a signal will be sent to the M-207A that indicates if the

flow is adequate If it is the M-207 STATUS screen (at power up) displays

COOL-OK. If it is not OK the screen will display COOL-FLT. Any time

there is a COOL-FLT the problem must be corrected in order to weld.


3. If coolant is not needed, turning the CW unit OFF will disconnect the fault

function. THE COOLANT FAULT ONLY WORKS IF THE CW IS

TURNED ON.


4. The above is the basic operation. The only decision to be made is whether

COOLANT is required. Some weld heads need it, some do not, depending

on the type of weld and duty cycle. Consult with an AMI representative as

to cooling requirements.

8.2

M-207-RP REMOTE PENDANT

WARNING

Always turn the power supply OFF before making any cable or connection changes

to the M-207A power supply.


1. Installation


1. Insert the M-207-RP cable connector into the M-207A panel connector

labeled REMOTE.


2. If a M-207-RP extension is used, it is installed between the M-207A and the

M-207-RP.


2. Operation

NOTE

A complete understanding of system operation is necessary for proper use of

the RP. Section IV and section V of this manual must be read and understood

before proceeding with RP operation.




8.3