MODEL 207A AND 207A-1

OPERATION MANUAL

Doc. No. 740044
Rev F

SECTION IV - SYSTEM FUNCTIONS

4.4

PANEL KEYS - The following are descriptions of all active operating keys

contained on the system (see figure 6).

1. ALL STOP KEY - Active only during weld sequence in test or weld mode.

When pressed it will stop the sequence, turn off the arc with no downslope

and start the postpurge process (see 4.3 event 7).

2. C KEY - Used for screen clear or cancel, it usually will end (without

storing) the screen will prompt the operator to indicate what will happen if

the C key is pressed.

3. CE KEY - The clear entry key is used to clear numbers entered with the

numeric keys before the enter key is pressed. Use this key when a mistake

is make using the numeric keys.

4. ENTER KEY - Used at the end of each step to indicate completion and to

move to the next step or screen.

5. F KEY - These are function keys numbered 1 to 16. Each key is aligned

with a portion of the display and are used to activate, cycle or alter the item

displayed above or below it. Each key will alter different functions

depending on what screen is being displayed. Use of the F keys is always

prompted by the screens.

6. L KEY - The M-207 is multi-lingual. Pressing this key will change the

display from English to French or to German if pressed again or to Swedish

or to Japanese if continued to be pressed.. The L key is always active..

7. LIB KEY - Used to access the LIBRARY (weld schedule memory/storage).


8. MANUAL PURGE KEY - Active at all times. Used for manually turning

on the gas solenoid. When ON, the gas solenoid will be energized and it

will stay ON until this key is manually pressed again.


9. NEXT LEVEL KEY - Active when weld schedules with more than one

level are being displayed. An * will appear on the display to indicate that

more levels are programmed for that weld schedule.


10. NEXT SCREEN KEY - Active when another screen (more data) is available

for a weld schedule or function. An * will appear on the display to indicate

that more data is available on the next screen.