Arc Machines 207 User Manual

Page 40

Advertising
background image

MODEL 207A AND 207A-1

OPERATION MANUAL

Doc. No. 740044
Rev F

SECTION V - OPERATION

5.3

WELD SCHEDULE SELECTION

4. To find the weld schedule you want press the NEXT SCREEN key. The next

weld schedule in memory will be displayed. Continue pressing the NEXT

SCREEN key until the desired weld schedule appears. When the desired

schedule appears, press the ENTER key. After a few seconds your selected

weld schedule will appear on the display.

5. When the weld schedule is called up from memory it will appear on the

screens like this:

# OD WALL TYPE MAT QTY READY
001 1.500 .065 TUBE SS 0010 TO TEST

USE NEST SCREEN FOR VALUES THEN F KEYS *

TO CHANGE VALUES - USE SEQ START TO WELD


READY TO TEST may say FAULT ______ with an explanation in the

_______ space as to what the fault is. The fault must be corrected before

proceeding.


5.4

VIEWING FUNCTION VALUES

NOTE

Insure that section 5.2, NEXT/PREV SCREEN/LEVEL has been

reviewed before proceeding.

1. Pressing the NEXT SCREEN key after the weld schedule has been selected

from the library will result in the following screen:

# OD WALL TYPE MAT QTY READY
001 1.500 .065 TUBE SS 0010 TO TEST

*LVL-TIME PRI--AMP--BCK PRI-PULSE-BCK*

01 000 000 000 0.00 0.00*

The above shows amperes, pulse times and level time (duration) for level 1 of

the schedule.

2. After reviewing this information the operator can do one of the following:


1. Make changes to these level 1 functions (see 5.5).




5.5