SECTION V - OPERATION


5.7

SET UP FUNCTIONS


2. SET UP FUNCTIONS IN PROGRAM MODE - If the System Mode is set to

PROGRAM these additional functions can be shown after the first two SET

UP screens.

1. START LEVEL - Right after the arc is struck an initial current is used to

stabilize the arc. This is called START LEVEL and can be programmed

for a value from 5 to 100 amperes. The START LEVEL current is only

used for a very short period of time but can make the difference between

good starts and bad starts. Always set this value as high as possible yet

still make good repeatable welds without excess penetration at the start.

2. SENSORS - The M-207A FAULT detection system (see 7.4) has an

EXTERNAL input feature that allows the user to monitor up to 3 external

functions (such as an Oxygen Analyzer) and create a M-207A FAULT if

that external feature should fail.

Pressing the F key under this will allow the user to turn any or all of the 3

Sensors ON and select whether the FAULT should occur with a LOW

input signal or HIGH input signal. Reference AMI drawing 45B072514

for pin connections and electrical signal information about High and Low.

3. PRINTER MODE - The M-207A can be set up to make a print out of the

Weld # automatically (AUTO) after every Sequence. If set to MANUAL a

print will only be made if the PRINT key is pressed after a weld sequence.

NOTE

The following SET UP functions are accessed, in PROGRAM MODE, by

pressing the NEXT SCREEN key from the third SET UP screen.

Remember they do not appear if the system mode is in OPERATE.

4. CANNED PROGRAMS - WELD #’S 71 to 100 can be LOCKED or

UNLOCKED. If LOCKED they cannot be MODIFIED, DELETED or

have new ones CREATED (even in the program mode). Even if

LOCKED they can still be copied to any available # between 1 and 70.


If UNLOCKED positions 71 to 100 become accessible to anyone with a

key for the MODE switch.


They are called CANNED programs because AMI ships the M-207A with

a few common weld procedures in these positions.




5.10