6.4

TRANSFER/RECEIVE WELD SCHEDULE MEMORY


4. Press the PRO key, then press the F key above or below the word TRANSFER

The Screen will then ask if you want to TRANSFER THE ENTIRE LIB,

RECEIVE THE ENTIRE LIB or RECEIVE ONE WELD #. Use the

appropriate F key to select your choice and then press the ENTER key.

CAUTION

Prior to TRANSFERRING data from the M-207A to the M-207-EMM the

M-207-EMM memory is erased. Any data stored in the EMM previously will

be LOST. The M-207-EMM is intended to copy the ENTIRE memory of an

M-207A.


Individual weld schedules CANNOT be added one at a time to the M-207-

EMM from the M-207A (TRANSFER mode). Individual weld schedules CAN

BE added one at a time to the M-207A from the M-207-EMM (RECEIVE

mode). See section 8.3 for more cautions.


6.5

DELETE A WELD SCHEDULE

CAUTION

USE OF THIS FUNCTION WILL RESULT IN THE LOSS OF A WELD

SCHEDULE IN MEMORY.


1. The DELETE function must start from the STATUS screen and the

OPERATE mode switch must be in the PROGRAM position.


2. Press the PRO key; then press the F key above or below the word DELETE.

Use the numeric keys to enter the weld schedule number to be DELETED. A

WARNING will appear that pressing ENTER will DELETE this Schedule;

VERIFY and then press the ENTER key or press the C key if you change your

mind.


Another WARNING will be given at this time to confirm that you wish to

DELETE this Schedule. Confirm and verify again and then press the ENTER

key again. THE WELD SCHEDULE WILL BE DELETED at this time.


3. Deletion of a Level with in a Schedule is part of the MODIFY option (see

section 6.2.2).