Arc Machines 207 User Manual

Page 42

Advertising
background image

MODEL 207A AND 207A-1

OPERATION MANUAL

Doc. No. 740044
Rev F

SECTION V - OPERATION


5.6

OVERRIDING FUNCTION VALUES, DURING WELD SEQUENCE

It is possible to over-ride the value of the following functions during Weld

Sequence:

Level Time

Primary Amps

Background Amps

Primary Pulse Time

Background Pulse Time

Primary RPM

Prepurge Time

Post Purge Time

Background RPM

Travel Start Delay

Overrides during sequence can only be done by use of the F KEYS (see in 5.5.3).

The numeric keypad cannot be used.

You cannot override during weld sequence the Pulse Mode, Travel Step Mode,
Upslope Time, Downslope Time or Travel Direction.

5.7

SET UP FUNCTIONS


There are two types of SET UP screens. Both are accessed with the SET UP key.

One type appears when the SYSTEM MODE is set to OPERATE and both appear

when the SYSTEM MODE is set to PROGRAM.

NOTE

The SET UP screens offer special functions that can ENHANCE or in some cases

CHANGE the way the M-207A operates. It is important for the user to

understand these features. Under some conditions, if not properly set,

undesirable performance can occur.


1. SET UP FUNCTIONS IN OPERATE MODE - Pressing the SET UP key on

the M-207A panel when on the STATUS SCREEN or WELD SCREEN with

the SYSTEM MODE set to OPERATE will access the first of two SET UP

screens that contain the following functions:


1.

CALC - Pressing the F key under this choice will access a prompt screen

for either calculating Tungsten Length, converting IPM to RPM or

calculating total Level Time. Select which one you wish to perform and

follow the on screen instructions.


2.

WELD SELECT - This feature is used to select up to 4 different weld

schedules to be accessible by the M-207-RP Option. See Section 8.2 for

more details.




5.7

Advertising