6 custom stream formatting, Table 10-8 on – Rice Lake 920i Installation Manual V3.10 User Manual

Page 115

Advertising
background image

Appendix

109

10.6 Custom Stream Formatting

Each port can be independently configured to stream a default frame format or can be customized to stream a

user-defined format. Custom formatting is very similar to the standard print formatting described in Section 6.0.
Table 10-8 on page 109 lists the format identifiers used to configure a custom stream format. See Section 10.7 on

page 112 for examples of custom stream formats.

Format Identifier

Defined By

Description

<P[G | N | T]>

STR.POS#n
STR.NEG#n

Polarity. Specifies positive or negative polarity for the current or
specified (Gross/Net/Tare) weight on the source scale. Possible
values are SPACE, NONE, + (for STR.POS#n), or – (for STR.NEG#n)

<U[P | S | T]>

STR.PRI#n
STR.SEC#n
STR.TER#n

Units. Specifies primary, secondary, or tertiary units for the current or
specified weight on the source scale.

<M[G | N | T]>

STR.GROSS#n
STR.NET#n
STR.TARE#n

Mode. Specifies gross, net, or tare weight for the current or
specified weight on the source scale.

<S>

STR.MOTION#n
STR.RANGE#n
STR.OK#n
STR.INVALID#n
STR.ZERO#n

Status for the source scale. Default values and meanings for each
status:
STR.MOTION#n

M

In motion

STR.RANGE#n

O

Out of range

STR.OK#n

<space>

OK

STR.INVALID#n

I

Invalid

STR.ZERO#n

Z

COZ

<B [–]n,…>

See descriptions below

Bit fields. Comma-separated sequence of bit field specifiers. Must
be exactly 8 bits. Minus sign ([–]) inverts the bit.

B0

Always 0

B1

Always 1

B2

Configuration

=1 if even parity

B3

Dynamic

=1 if MODE=NET

B4

Dynamic

=1 if COZ

B5

Dynamic

=1 if standstill

B6

Dynamic

=1 if gross negative

B7

Dynamic

=1 if out of range

B8

Dynamic

=1 if secondary/tertiary

B9

Dynamic

=1 if tare in system

B10

Dynamic

=1 if tare is keyed

B11

Dynamic

=00 if MODE=GROSS
=01 if MODE=NET
=10 if MODE=TARE
=11 (not used)

B12

Dynamic

=00 if UNITS=PRIMARY
=01 if UNITS=SECONDARY
=10 if UNITS=TERTIARY
=11 (not used)

B13

Configuration

=00 (not used)
=01 if current DSPDIV=1
=10 if current DSPDIV=2
=11 if current DSPDIV=5

Table 10-8. Custom Stream Format Identifiers