–REL

Negative relative setpoint. Performs functions based on a specified value below
a referenced setpoint, using the same weight mode as the referenced setpoint.

X

X

%REL

Percent relative setpoint. Performs functions based on a specified percentage
of the target value of a referenced setpoint, using the same weight mode as the
referenced setpoint. The actual target value of the %REL setpoint is calculated
as a percentage of the target value of the referenced setpoint.

X

X

RESREL

Relative to a result setpoint. Performs functions based on a specified
percentage of the captured value of a referenced setpoint, using the same
weight mode as the referenced setpoint. The actual target value of the RESREL
setpoint is calculated as a percentage of the captured value of the referenced
setpoint, rather than the target value.

X

X

PAUSE

Pauses the batch sequence indefinitely. A BATSTRT signal must be initiated to
continue the batch process.

X

DELAY

Delays the batch sequence for a specified time. The length of the delay (in
tenths of a second) is specified on the VALUE parameter.

X

WAITSS

Wait for standstill. Suspends the batch sequence until the scale is at standstill.

X

COUNTER

Specifies the number of consecutive batch sequences to perform. Counter
setpoints should be placed at the beginning of a batch routine.

X

AUTOJOG

Automatically checks the previous weight-based setpoint to verify the setpoint
weight value is satisfied in a standstill condition. If the previous setpoint is not
satisfied when at standstill, the AUTOJOG setpoint activates the digital output
of the previous weight-based setpoint for a period of time, specified on the
VALUE parameter. The autojog process repeats until the previous weight-based
setpoint is satisfied when the scale is at standstill.

NOTE: The AUTOJOG digital output is typically used to signify that an autojog
operation is being performed. AUTOJOG should not be assigned to the same
digital output as the related weight-based setpoint.

X

COZ

Center of zero. Monitors for a gross zero condition. The digital output
associated with this setpoint kind is activated when the referenced scale is a
center of zero. No value is required for this setpoint.

X

INMOTON

In motion. Monitors for an in-motion condition. The digital output associated
with this setpoint is activated when the scale is not at standstill. No value is
required for this setpoint.

X

INRANGE

In range. Monitors for an in-range condition. The digital output associated with
this setpoint is activated when the scale is within capacity range. No value is
required for this setpoint.

X

BATCHPR

Batch processing signal. The digital output associated with this setpoint is
activated whenever a batch sequence is in progress. No value is required for
this setpoint.

X

TIMER

Tracks the progress of a batch sequence based on a timer.

The timer value, specified in tenths of a second on the VALUE parameter,
determines the length of time allowed between start and end setpoints. The
indicator START and END parameters are used to specify the start and end
setpoints. If the END setpoint is not reached before the timer expires, the digital
output associated with this setpoint is activated.

X

Kind

Description

Batch

Continuous

Table 8-1. Setpoint Kinds (Continued)