Rice Lake 920i Installation Manual V3.10 User Manual

Page 94

Advertising
background image

88

920i

Installation Manual

SC.ZRANGE#n

Zero range

1.900000, 0–100

SC.MOTBAND#n

Motion band

1, 0–100

SC.SSTIME#n

Standstill time

1–65535

SC.OVRLOAD#n

Overload

FS+2%, FS+1D, FS+9D, FS

SC.WMTTHRH#n

Weighment threshold

grads

SC.NUMWEIGH#n

Number of weighments

SC.MAX_WEIGHT#n

Maximum weight

SC.DIGFLTR1#n
SC.DIGFLTR2#n
SC.DIGFLTR3#n

Digital filtering

1, 2, 4, 8, 16, 32, 64, 128, 256

SC.DFSENS#n

Digital filter cutout sensitivity

2OUT, 4OUT, 8OUT, 16OUT, 32OUT, 64OUT, 128OUT

SC.DFTHRH#n

Digital filter cutout threshold

NONE, 2D, 5D, 10D, 20D, 50D, 100D, 200D, 250D

SC.RATLTRAP#n

Rattletrap filtering

OFF, ON

SC.SMPRAT#n

Sample rate

30HZ, 60HZ, 120HZ, 240HZ, 480HZ, 960HZ

SC.PWRUPMD#n

Power up mode

GO, DELAY

SC.TAREFN#n

Tare function

BOTH, NOTARE, PBTARE, KEYED

SC.PRI.DECPNT#n

Primary units decimal position

8.888888, 88.88888, 888.8888, 8888.888, 88888.88, 888888.8,
8888888, 8888880, 8888800

SC.PRI.DSPDIV#n

Primary units display divisions

1D, 2D, 5D

SC.PRI.UNITS#n

Primary units

LB, KG, G, OZ, TN, T, GN, TROYOZ, TROYLB, LT, CUSTOM, NONE,
OFF

SC.PRI.CUNITS#n

Primary custom units

Specify units if SC.PRI.UNITS=CUSTOM

SC.SEC.DECPNT#n

Secondary units decimal
position

8.888888, 88.88888, 888.8888, 8888.888, 88888.88, 888888.8,
8888888, 8888880, 8888800

SC.SEC.DSPDIV#n

Secondary units display
divisions

1D, 2D, 5D

SC.SEC.UNITS#n

Secondary units

LB, KG, G, OZ, TN, T, GN, TROYOZ, TROYLB, LT, CUSTOM, NONE,
OFF

SC.SEC.CUNITS#n

Secondary custom units

Specify units if SC.SEC.UNITS=CUSTOM

SC.SEC.MULT#n

Secondary units multiplier

0.00000–9999999

SC.TER.UNITS#n

Tertiary units

LB, KG, G, OZ, TN, T, GN, TROYOZ, TROYLB, LT, CUSTOM, NONE.
OFF

SC.TER.CUNITS#n

Tertiary custom units

Specify units if SC.TER.UNITS=CUSTOM

SC.TER.DECPNT#n

Tertiary units decimal position

8.888888, 88.88888, 888.8888, 8888.888, 88888.88, 888888.8,
8888888, 8888880, 8888800

SC.TER.DSPDIV#n

Tertiary units display divisions

1D, 2D, 5D

SC.TER.MULT#n

Tertiary units multiplier

0.000001–9999999

SC.ROC.DECPNT#n

Tertiary units decimal position

8.888888, 88.88888, 888.8888, 8888.888, 88888.88, 888888.8,
8888888, 8888880, 8888800

SC.ROC.DSPDIV#n

Rate-of-change units display
divisions

1D, 2D, 5D

SC.ROC.MULT#n

Rate-of-change units multiplier 0.000001–9999999

SC.ROC.UNITS#n

Rate-of-change units

SEC, MIN, HOUR

SC.ROC.INTERVL#n

Rate-of-change interval

1–100

Command

Description

Values

Table 9-3. SCALES Serial Commands (Continued)