0 print formatting, 1 print formatting commands, Print formatting – Rice Lake 920i Installation Manual V3.10 User Manual

Page 65

Advertising
background image

Print Formatting

59

6.0

Print Formatting

The

920i

provides print formats that determine the format of the printed output when the

PRINT

key is pressed, a

KPRINT serial command is received, or when setpoint push-print or truck weigh-in or weigh-out operations are

performed. Supported print formats are: GFMT, NFMT, ACCFMT, SPFMT, TRWIN, TRWOUT, ALERT,

AUXFMT1—AUXFMT20, and AUDITFMT. Additionally, two header formats, HDRFMT1 and HDRFMT2,

can be inserted into any of the other ticket formats using the <H1> and <H2>formatting commands. The

particular ticket format used for a given print operation depends on the indicator configuration (see Table 6-2 on

page 61) and the particular operation performed.
Each print format can be customized to include up to 1000 characters of information, such as company name and
address, on printed tickets. You can use the

iRev

configuration utility, serial commands, or the indicator front panel

(PFORMT menu) to customize the print formats.

6.1

Print Formatting Commands

Table 6-1 lists commands you can use to format the

920i

print formats. Commands included in the format strings

must be enclosed between < and > delimiters. Any characters outside of the delimiters are printed as text on the

ticket. Text characters can include any ASCII character that can be printed by the output device.

Command

Description

Supported Ticket Formats

General Weight Data Commands

<G>

Gross weight, current scale

GFMT, NFMT, TRWIN. TRWOUT, ACCFMT,
AUXFMTxx, ALERT

<G#n>

Gross weight, scale n

<N>

Net weight, current scale

<N#n>

Net weight, scale n

<T>

Tare weight, current scale

<T#n>

Tare weight, scale n

<S>

Current scale number

NOTES:
Gross, net, tare, accumulator, truck, and setpoint weights can be printed in any configured weight units by adding the following
modifiers to the gross, net, and tare weight commands: /P (primary units), /D (displayed units), /S (secondary units), /T (tertiary
units). If not specified, the current displayed units (/D) is assumed. Example: To format a ticket to show net weight for Scale #3
in secondary units, use the following command: <N#3/S>

Formatted weight strings contain a 10-digit weight field (including sign and decimal point, with leading zeroes suppressed),
followed by a space and a two-digit units identifier. Total field length with units identifier is 12 (or 13) characters.

Accumulator Commands

<A>

Accumulated weight, current scale

GFMT, NFMT, ACCFMT, AUXFMTxx

<A#n>

Accumulated weight, scale n

<AA>

Average accumulation, current scale

<AA#n>

Average accumulation, scale n

<AC>

Number of accumulations, current scale

<AC#n>

Number of accumulations, scale n

<AT>

Time of last accumulation, current scale

<AT#n>

Time of last accumulation, scale n

<AD>

Date of last accumulation, current scale

<AD#n>

Date of last accumulation, scale n

Truck Mode Commands

Table 6-1. Print Format Commands

Advertising