40

920i

Installation Manual

FEATURE Menu

Parameter

Choices

Description

Level 2 submenus

DATE

DATEFMT
DATESEP

Allows selection of date format and date separator character. See Level 3 submenu
parameter descriptions.

Use the TIME/DATE softkey or the SD serial command to set the date. See Section 9.0 on
page 86
for information about using the serial commands.

TIME

TIMEFMT
TIMESEP

Allows selection of time format and separator character. See Level 3 submenu parameter
descriptions.

Use the TIME/DATE softkey or the ST serial command to set the time. See Section 9.0 on
page 86
for information about using the serial commands.

DECFMT

DOT
COMMA

Specifies whether decimal numbers are displayed using a period (DOT) or comma as the
decimal symbol.

DSPRATE

1
1–80

Display update rate. Specifies the display update rate, in the number of 100-millisecond
intervals between updates. The default value, 1, provides about 10 updates per second.
The maximum value updates the display every 8 seconds.

CONSNUM

0
0–9999999

Consecutive numbering. Allows sequential numbering for print operations. The consecutive
number value is incremented following each print operation that includes <CN> in the ticket
format. When the consecutive number is reset, it is reset to the value specified on the
CONSTUP parameter.

CONSTUP

0
0–9999999

Specifies the consecutive number start-up value used when the consecutive number is
reset by sending the KCLRCN serial command or a CLRCN digital input. Value specified
must be in the range 0–9 999 999.

UID

1
unit-ID

Specifies the unit identification number. Value specified can be any alphanumeric value, up
to eight characters.

TRUCK

OFF
MODE1
MODE2
MODE3
MODE4
MODE5
MODE6

Specifies the truck mode used. If selected, the indicator switches from normal mode to the
selected truck mode. See Section 7.0 on page 65 for more information about using the
truck modes.

MODE1: Auto clear ID, keyed tares, value swapping
MODE2: Auto clear ID, no keyed tares, value swapping
MODE3: Stored ID, keyed tares, value swapping
MODE4: Stored ID, no keyed tares, value swapping
MODE5: Stored ID, keyed tares, no value swapping
MODE6: Stored ID, no keyed tares, no value swapping

ALIBI

OFF
ON

Specifies whether data storage is used by the alibi feature to allow reprinting of any
transaction.

Use the SOFTKEYS parameter to enable a softkey for recalling alibi print transactions.

CFGPWD

0
0–9999999

reset=999999

Configuration password. Specify a non-zero value to restrict access to all configuration
menus. The value 999999 is used to reset the indicator

NOTE: If a configuration password is specified, be sure to record the password and keep it
in a safe place. If the configuration password is lost or unavailable, the indicator must be
cleared (reset configuration and calibration parameters) to continue use.

To clear the indicator, press the setup switch, then enter 999999 (six nines) at the
configuration password prompt. The unit performs a RESETCONFIGURATION then returns
to the setup mode configuration display.

Table 3-7. FEATURE Menu Parameters