1 operating modes – Rice Lake 920i Installation Manual V3.10 User Manual

Page 8

Advertising
background image

2

920i

Installation Manual

• Single- and dual-channel A/D cards to drive up to

sixteen 350

Ω load cells per A/D card. A/D cards

support both 4- and 6-wire load cell connections.
A/D cards are matched to allow interchangeability

without having to recalibrate the scale. Calibration

includes support for latitude and elevation

compensation, millivolt calibration, and five-point

linearization.

• Analog output card for 0–10 VDC or 0–20 mA

tracking of gross or net weight values.

• Dual-channel serial expansion card provides one

additional RS-485 port or two ports for either

RS-232 or 20mA communications at up to

19200 bps.

• 24-channel digital I/O expansion card.
• 1MB memory expansion card for expanded

database capability.

• Pulse input card for use with pulse count and

pulse rate setpoints.

• Dual-channel analog input card supports 0–10

VDC, 0–20 mA, ambient temperature, and four

types of thermocouple.

• Bus interface cards for Ethernet,

EtherNet/IP

1

, DeviceNet

2

, Allen-Bradley

R e m o t e I / O

3

, P r o f i b u s

®

D P

4

, a n d

ControlNet

5

networks.

See Section 2.5 on page 13 for detailed information

about expansion board configurations. Part numbers

of available option cards and expansion boards are

listed in Section 1.4 on page 4.

Front Panel

The

920i

front panel, shown in Figure 1-1, consists of

a 27-button keypad with a large backlit LCD display.

The keys are grouped as five configurable softkeys,

five primary scale function keys, four navigation keys,

and numeric entry keys. The display can be

graphically configured using

iRev

software.

Weight information is displayed with a graphical scale

in six font sizes up to 1.2 inches. Up to four scale

widgets can be displayed in legal-for-trade,

multiple-scale applications. Status areas on the display

are used for operator prompts and entering data. The

remainder of the display can be graphically

configured for representation of a specific application.

Display contrast can be adjusted with the LCD

contrast potentiometer.

Figure 1-1. 920i Front Panel

Enclosures

The

920i

is available in four enclosures: universal

(tilt-stand), deep enclosure, panel mount, and wall

mount. Stainless steel enclosures are rated for NEMA

4X/IP66. This manual provides assembly drawings

and replacement parts lists for the universal model;

supplemental documentation provides information

specific to the panel mount and wall mount models

(Section 1.4 on page 4).

1.1

Operating Modes

The

920i

has two modes of operation:

Normal mode

Normal mode is the weighing mode of the

indicator. The indicator displays gross, net, or tare

weights as required, using the secondary display

to indicate scale status and the type of weight

value displayed. Once configuration is complete

and a legal seal is affixed to the large fillister-head

screw on the indicator enclosure, this is the only

mode in which the

920i

can operate.

Setup mode

Most of the procedures described in this manual

require the indicator to be in setup mode,

including configuration and calibration.
To enter setup mode, remove the large fillister

head screw from the enclosure. Insert a

screwdriver or a similar tool into the access hole

and press the setup switch once. The indicator

display changes to show scale configuration

menus.

1.

EtherNet/IP™ is a trademark of ControlNet
International, Ltd., under license by the Open
DeviceNet Vendor Association.

2.

DeviceNet™ is a trademark of the Open DeviceNet
Vendor Association.

3.

Allen-Bradley

®

, PLC

®

, and SLC

are trademarks of

Allen-Bradley Company, Inc., a Rockwell International
company.

4.

Profibus

®

is a registered trademark of Profibus

International.

5.

ControlNet™ is a trademark of ControlNet
International

PRINT

UNITS

SOFTKEY1 SOFTKEY2 SOFTKEY3 SOFTKEY4 SOFTKEY5