Installation and Operation Manual- Integrator Hardware Installation

17

2.3

Junction Box Installation

The In-Motion Belt Scale uses the TuffSeal

JB4SS (PN 88956) junction box. It is a four-channel signal trim

junction box with an expansion board enclosed. The junction box is a stainless steel NEMA 4X enclosure that
comes with a standard Prevent

®

breather vent which inhibits the buildup of pressure cause by sudden temperature

or environmental changes.

Figure 2-4. TuffSeal Junction Box

Use the following steps to install the junction box.

1. Set the junction box onto the uni-strut center bar and attach to the bar using the enclosed screws.

2. Attach the ground lug (shown below).

Figure 2-5. Attach the Ground Lug onto the Junction Box