background image

24

Installation and Operation Manual

Proximity Sensor Located on Wheel

1. The wheel speed sensor should be mounted to ride against the inside of the return conveyor belting.

2. Install the wheel bracket assembly to the tail end side of the scale carriage. The belt travel should pull the

wheel away from the scale carriage.

Speed Wheel

Sensor

Figure 2-16. Speed Wheel Sensor

3. Mount the wheel arm to the cross brace closest to the tail of the conveyor. The wheel assembly must be

free to move in the vertical direction and must maintain contact with the belt at all times.