2 integrator calibration – Rice Lake BCi Belt Scale - Installation and Operation Manual Version 2.03 User Manual
Page 55
Installation & Operation Manual - Calibration
49
.
End
SCALE #1
Home
11/23/2011
08:13AM
96489 Pulse
261 Per Sec
889.25
Time Running
Cancel
Enter Number of Revolutions
=> 1.0
Figure 5-2. Enter Number of Revolutions
6. The operator will key in the number of times the belt traveled past the reference point.
7. The integrator will then calculate the pulses per unit of measure. This will be used for displaying the
speed of the belt and totalizing the weight during operation.
8. The number of belt revolutions and the test duration are stored. These values are used for auto calibration
when the integrator is being calibrated to the load cell.
5.2
Integrator Calibration
There are three modes of integrator calibration:
•
Auto cal
•
Material cal
•
Zero cal
All three calibration methods are described in the following sections as are their softkey locations
11/23/2011
08:13AM
Exit=>
Test Time
Test Accumulator
Old Span Error %
Auto Cal
Span Error %
13.50
117.4
3574
25.00
Progress
Material
Zero Cal
.
Figure 5-3. Calibration Method Softkeys