4.49 Remote Totalizer Reset Input

This parameter defines a digital input bit that can be
used to reset the reset totalizer. This only affect the
reset totalizer and not the master totalizer. The master
totalizer can only be reset through the supervisor
menu.

The default value of this parameter is: 0.

4.50 Integrator Identification

The integrator ID can be an alpha-numeric string up to
8 characters.

Press the

enter

key and enter the identification ID and

press the

enter

key again to save this ID.

It can be used for printing or streaming information
using the token <UID>.

4.51 Preact Length

This parameter is used to dynamically adjust the target
value based on the rate of the belt scale.

Enter the distance from the feed gate to the midpoint
of the weigh idler and the first dual idler. Enter the
preact length in feet and press the

enter

key to save

that parameter.

4.52 Enable Batching

Set to On to enable batching When enabled, the
system can control gates for filling applications.

When enabled, the operator will see

Start Fill

and

Target

Settings

softkeys on the display.

The default value is Off.

4.53 Analog 1 Mode

This parameter defines what the optional analog
output #1 tracks.

Three settings are available with this parameter. They
are:

Rate - Tracks to the maximum rated
c a p a c i t y o f t h e b e l t s c a l e ( s e e
Section 4.2).

Load - Tracks to the maximum total cell
build of the system (see Section 4.4)

Speed - Tracks to the maximum speed
value (see Section 4.37)

4.54 Analog 2 Mode

This parameter defines what the optional analog
output #2 tracks.

Three settings are available with this parameter. They
are:

Rate - Tracks to the maximum rated
c a p a c i t y o f t h e b e l t s c a l e ( s e e
Section 4.2).

Load - Tracks to the maximum total cell
build of the system (see Section 4.4)

Speed - Tracks to the maximum speed
value (see Section 4.37)

4.55 Master Totalizer Reset

To reset the Master Totalizer, press the

Master Totalizer

softkey from the Supervisor Mode to access this
parameter. The integrator prompts

Clear Master

Totalizer

?

No

SCALE #1

Yes

11/23/2011

08:13AM

Admin. Passcode (numeric)

Rate Unit Time

Speed Unit Time

Unit of Measure

Unit of Rate

Rate Count By

Totalizer Count By

Load Display Units

Load Count By

Calibration Weight

Hr

Sec

M

kg

0.1

0.1

lb

0.1

20.0

Clear Master Totalizer?

Press

Yes

to clear the totalizer or

No

to leave the

accumulated weight in the master totalizer.