Installation and Operation Manual

Wiring the Junction Box

The four channel TuffSeal JB4SS has been designed to connect and trim up to four load cells per board.
However, it is possible to use this junction box with other combinations.

Run the load cell cables from the load cells through the channels on the scale carriage over to the junction box.

Run load cell

c a b l e

t h ro u g h

s c a l e

c a r ri a g e

channel

Figure 2-6. Route Load Cell Cable From Load Cell to Junction Box

3. Open the cover to the junction box to expose the interior.

4. Wire the junction box by running the load cell cable inside of the junction box.

Figure 2-7. Junction Box Interior

Use Table 2-1 to wire the load cell cables.

Table 2-1. Load Cell Wiring

Wire Color

Signal

Red

+EX

Black

-EX

Green

+SIG

White

-SIG

Silver Braid

SHIELD