Wiring the junction box, Figure 2-5. wiring the junction box – Rice Lake BCi Belt Scale - Installation and Operation Manual Version 2.03 User Manual
Page 24
18
Installation and Operation Manual
Wiring the Junction Box
The four channel TuffSeal JB4SS has been designed to connect and trim up to four load cells per board.
However, it is possible to use this junction box with other combinations.
Run the load cell cables from the load cells through the channels on the scale carriage over to the junction box.
Run load cell
c a b l e
t h ro u g h
s c a l e
c a r ri a g e
channel
Figure 2-6. Route Load Cell Cable From Load Cell to Junction Box
3. Open the cover to the junction box to expose the interior.
4. Wire the junction box by running the load cell cable inside of the junction box.
Figure 2-7. Junction Box Interior
Use Table 2-1 to wire the load cell cables.
Table 2-1. Load Cell Wiring
Wire Color
Signal
Red
+EX
Black
-EX
Green
+SIG
White
-SIG
Silver Braid
SHIELD