1 admin. passcode (numeric), Rate – Rice Lake BCi Belt Scale - Installation and Operation Manual Version 2.03 User Manual
Page 46
40
Installation and Operation Manual
4.1
Admin. Passcode (numeric)
This parameter allows the administration password to be configured. It prevents unauthorized changes to system
parameters and calibration. Select the
Admin.Passcode (numeric)
prompt shown in Figure 4-4 and you will be
prompted to enter a password (shown in Figure 4-3).
SCALE #1
Exit =>
11/23/2011
08:13AM
Rate
Speed
Load
Totalizer
tn/hr
ft/min
lb/ft
tn
19346.2
43.21
47.5
17467.8
Enter Password
Figure 4-3. Enter Password
Once the password is entered into the integrator, the following menu screen appears again. There are several
parameters that can be entered and are explained in the following sections.
Exit=>
SCALE #1
Master
Totalizer
Integrator
Calibration
Time/Date
Belt
Calibration
11/23/2011
08:13AM
Admin. Passcode (numeric)
Scale Capacity (Max Rate)
Load Cell MV
Total LC Build
Rate Unit Time
Filter (s)
Filter Threshold (divisions)
Speed Unit Time
Fixed Speed
Unit of Measure
100.00
3.00000
600
hr
2.0
5
min
100.00
ft
Figure 4-4. Main Supervisor Screen
Use the
up
and
down
arrows on the integrator to scroll through the menu items. The available parameters are
displayed by pressing the