Installation

9

2.3.1

Serial Communications

The CB-2 supports RS-232 communications and their connections are shown in Figure 2-6, below.

Figure 2-6. Terminal Block RS-232 Connections

Serial ports are configured using the SERIAL menu which is shown in Table 2-4.

Note: For CB-2 units with the weighed water option, serial connections remain the same using the same 9 pins as is shown in
Figure 2-5.

Top Connector - Serial Communications

Description

Port #

Port Connector

Pin Number

Signal

PC

Port 1

J11

1

GND

2

RXD

3

TXD

Ticket and

Report

Printer

Port 4

J10

4

GND

5

RXD

6

TXD

Preprinted

Ticket Printer

Port 3

J9

7

GND

8

RXD

9

TXD

iRev or

Keyboard

Port 2

_

10

Not Used

11

Not Used

12

Not Used

Table 2-4. Serial Communications Connections

TX

RX

GND

TX

RX

GND

TX

RX

GND

Pin 1

1

2

3

4

5

6

7

8

9

11

12

10

Advertising