28

CB-2 Automated Concrete Batching System Installation/Operation Manual

Locations

You have the ability to Add, Copy, Change, Delete or Exit

Level 4 Sub-menu ADMIN MENU/APPLICATION PARAMETERS/DATABASES/LOCATIONS

Location ID

Store
Change

Enter in the bin/silo ID location. Press Store to keep that value or press
Change to change the value to a different one.

Name

Store
Change

Enter in the bin/silo name/description. Press Store to keep that value or press
Change to change the value to a different one.

Material

Store
Material

Enter in the material code. Press Store to keep that value or press Material to
change the material to a different one.

Delivery Mode

Change
Store

Enter in the delivery mode. Press Store to keep that value or press Change to
change the delivery mode to a different one.
1 - Single Speed

Secondary Mode

Off
On

Continuous Aeration
No Flow Aeration
Continuous Vibrator
No Flow Vibrator

Scale

Store
Scale

Enter in the scale. Press Store to keep that value or press Scale to change
the scale to a different one.

Fast Feed Gate

Change

Enter New Fast Feed Gate number.

Aerator

Change

Select to change aerator.

Feed Gate Limit Switch

Change

Select ot change the feed gate limit switch.

Fast Feed SP

Store
Change

Select to change the set point number that is used for fast filling.

Moisture Probe ID

Store
Change

Is a meter used to determine the moisture content of aggregates.
Press Store to keep the current parameter, or press Change to change the ID
and then press enter to save the new parameter.

Probe Mode

No Probe
Static Only
Static Flow
Flow Only

Moisture compensation mode.

Total Moisture

Store
Change

Enter in the total moisture. Press Store to keep that value or press Change to
change the total moisture value to a different one.

Scales

Select or Enter scale number. 1-Agg, 2-Cement

Level 4 Sub-menu ADMIN MENU/APPLICATION PARAMETERS/DATABASES/SCALES

Scale Number

Store
Change

Enter in the scale number. Press Store to keep that value or press Change to
change the scale number to a different one.

Name

Store
Change

Enter in the name/description of the scale. Press Store to keep that value or
press Change to change the name to a different one.

Capacity

Store
Change

Enter in the capacity of the scale. Press Store to keep that value or press
Change to change the capacity of the scale to a different one.

Zero Tolerance Band

Store
Change

Enter in the zero tolerance band. Press Store to keep that value or press
Change to change the value of the zero tolerance band to a different one.

Cleanout Time

Store
Change

Enter the cleanout amount time in seconds. Press Store to keep that value or
press Change to change the cleanout time to a different one.

Close Time

Store
Change

Enter the Close Time amount time in seconds. Press Store to keep that value
or press Change to change the close time to a different amount.

Discharge Delay

Store
Change

This is the amount of time the system waits before starting the first admixture
discharge. To change the amount of time (sec.), enter a new numeric value
and press the

enter

button to save the value.

Start Discharge % Full

Store
Change

Enter the discharge percent for the cement scale. Press Store to keep that
value or press Change to change the percent to a different amount.

ADMIN Menu

Parameter

Choices

Description