Configuration of User Parameters

23

Application Parameters

ADMIN Menu

Parameter

Choices

Description

Level 2 Sub-menu

APPLICATION PARAMETERS

Level 3 Sub-menu

Batching Preferences

Level 4 Sub-menu ADMIN MENU/APPLICATION PARAMETERS/BATCHING PREFERENCES

Order Based Loading

No
Yes

Select Yes for order based loading to track order quantity, customer and job
ID.

Metric (S.I.) System

No
Yes

Select Yes to measure in metric units when kilograms are the primary unit of
measure.

State Regulatory Mode

Standard
MnDot
CAL TRAN
NYSDOT

Selects the desired state regulatory mode to weigh in.The CB-2 will function
slightly different to satisfy the selected state’s requirements.

Prompt for Truck ID

No
Yes

Selecting Yes for this option allows user to enter a character truck ID. At the
start of each batch the truck ID and driver name are then printed on the
batched ticket.

NET Mode Batching

No
Yes

Not used.

Split Batching Allowed

No
Yes

Selecting Yes for this option allows the user to split up a batch up to four
times the size of the plant.

Split Batch Even 1/4

No
Yes

Selecting Yes for this option allows the system to round the draft yards to the
nearest 1/4 yard to prevent odd draft sizes.

‘Discharge’ Keypress Required

Never
First Batch
Always

Select one of the options when a “discharge” keypress is required.

Aggregate Conveyor Control

Manual
Auto

Can select between Manual and Auto of the aggregate discharge conveyor. If
Manual is selected, the CB-2 does not attempt to start the conveyor. If Auto is
selected the CB-2 turns the aggregate discharge conveyor on and off as
needed. Note: if Auto is selected, it is critical that an audible alarm and light be
wired to the system alarm output to warn that the conveyor will be started.

Maintain Conveyor Power

No
Yes

Select Yes to maintain power to the conveyor system when the conveyor
should be running.

Boot Control

Manual
Auto

You can determine if you want the discharge boot to run manually or on auto,
otherwise a start pulse is sent to start the conveyor and another stop pulse is
sent to stop the conveyor.

Pipe Line/Preweigh Next Batch

No
Yes

Select Yes to pipeline the next batch.

Weigh-up Dust Collecting

No
Yes

Select Yes to do dust collection during the weigh up cycle.

Scale Inspect Mode

No
Yes

Select Yes to access the batch inspect mode. The inspect mode is useful for
state inspections that want to verify under/over tolerances.

ESTOP is Fatal

No
Yes

EStop will automatically abort the batch if yes is selected.

Air Pressure Sensor

No
Yes

Select Yes if the air pressure sensor is preset and should be used as an
interlock.

Auto Correct Jog Weights

No
Yes

Select Yes to do an auto correction of jog weights.

Zero Tolerance Override

No
Yes

Select Yes to allow a zero tolerance error, at the start of a batch to be
bypassed.

Table 4-1. Application Parameters Sub-menu List