0 configuration of scale parameters, 1 configuration methods, 1 irev configuration – Rice Lake CB-2 Concrete Batch Controller Version 1.0 User Manual

Page 21: Configuration of scale parameters, Irev configuration

Advertising
background image

Configuration of Scale Parameters

17

3.0

Configuration of Scale Parameters

The CB-2 is designed as a universal controller for all types of automated concrete production. There are many

settings and features that are only used by special applications. The factory default settings assume a two-scale

transit mix application and most of the default values will not need to be changed for this type of application. In

addition, system software has been pre-loaded along with a default database.
However, for the CB-2 to batch accurately, certain critical parameters must be determined and the plant must be

tuned (see tune plant section). As part of the default configuration, a minimum number of materials, physical

locations, and mix designs have been added. The mapping of the actual physical plant controls to the I/O points

in the software is also setup in the initial configuration.
To set up a standard configuration the

920i

indicator, the indicator must be placed in setup mode. The setup

switch is accessed by removing the large fillister head screw on the back of the enclosure. Switch position is

changed by inserting a screwdriver into the access hole and pressing the switch.
When the indicator is placed in setup mode, a series of menus is shown across the top of the display, along with

the words

Scale Configuration

. The SCALES menu is highlighted as the first used to configure the indicator.

Detailed descriptions of these menus are provided in Section 3.2.
When configuration is complete, press the

Exit

or

Save and Exit

softkey to exit setup mode, then replace the setup

switch access screw.

• The

Exit

softkey exits setup mode without saving parameter changes to NV RAM. Changes made to the

configuration remain in the system until indicator power is cycled.

Save and Exit

writes all parameter changes to NV RAM before returning to normal mode.

3.1

Configuration Methods

The

920i

indicator can be configured by using the front panel keys to navigate through a series of configuration

menus or by sending commands or configuration data to an indicator serial port. Configuration using the menus

is described in Section 3.1.2.
Configuration using the serial port can be accomplished using either the serial command set described in the

iRev

configuration utility.

NOTE:

Some configuration parameters, such as those used to configure the

920i

display and widgets, cannot be

accessed through the configuration menus.

iRev

provides the most complete and efficient configuration interface

for the

920i

.

3.1.1

iRev Configuration

The

iRev

configuration utility provides the preferred method for configuring the

920i

indicator.

iRev

runs on a

personal computer to set configuration parameters for the indicator. When

iRev

configuration is complete,

configuration data is downloaded to the

920i

indicator.

iRev

supports both uploading and downloading of indicator configuration data. This capability allows

configuration data to be retrieved from one indicator, edited, then downloaded to another indicator with an

identical hardware configuration.