IQ plus 355 Installation Manual

Level 3 submenus

Primary Units (PRIMAR Parameter)

DECPNT

888888
888880
8.88888
88.8888
888.888
8888.88
88888.8

Decimal point location. Specifies the location of the decimal point or dummy zeroes in the
primary unit display. Value should be consistent with local legal requirements.

DSPDIV

1D
2D
5D

Display divisions. Selects the minimum division size for the primary units displayed weight.

Note: Additional display divisions are available by entering the EDP command 2349171 in
configuration. Selection for 3,4,6,7,8,9,25, and 35 are available when this configuration
command is saved.

UNITS

LB
KG
OZ
TN
T
G
NONE

Specifies primary units for displayed and printed weight. Values are: LB=pound;
KG=kilogram; OZ=ounce; TN=short ton; T=metric ton; G=gram.

NOTE:

Indicators sold outside North America are configured with KG for both primary and

secondary units.

Secondary Units (SECNDR Parameter)

DECPNT

88888.8
888888
888880
8.88888
88.8888
888.888
8888.88

Decimal point location. Determines the location of the decimal point or dummy zeros in
the secondary unit display.

DSPDIV

5D
1D
2D

Display divisions. Selects the value of minimum division size of the displayed weight.

UNITS

KG
OZ
TN
T
G
OFF
NONE
LB

Specifies secondary units for displayed and printed weight. Values are: KG=kilogram;
OZ=ounce; TN=short ton; T=metric ton; G=gram; LB=pound.

MULT

0.453592
Enter other
choices via
keyboard

Multiplier. Specifies the conversion factor by which the primary units are multiplied to
obtain the secondary units. The default is 0.453592, which is the conversion factor for
changing pounds to kilograms. NOTE: This parameter does not display the decimal point
location for some values less than 1; use the MULEXP parameter to shift the decimal
position of the multiplier. See Section 7.6 on page 41 for a list of multipliers.

To toggle between primary and secondary units, press the UNITS key.

MULEXP

decimal
position

Multiplier exponent. Sets the decimal position for multiplier values.

FORMAT Menu

Parameter

Choices

Description

Table 3-3. Format Menu Parameters (Continued)

Advertising