10 software revision history – Rice Lake IQ Plus 355 Installation Manual V1.17 User Manual

Page 49

Advertising
background image

Appendix

45

7.10

Software Revision History

For a complete description of recent software revisions, visit our web site at

www.rlws.com.

The following list summarizes principal revision software changes:

Version 1.10

Entering setup mode now clears any tare value in the system.

The configured end-of-line delay (EOLDLY) now functions in both demand and continuous mode.

A/D gain (ADGAIN) and A/D offset (ADOFFS) functions removed from TEST menu.

Version 1.12

New SMPRAT parameter on the CONFIG menu provides selectable A/D conversion rate ranging from

3.75–30 Hz.

Default value for REGULAT parameter (on PROGRM menu) changed to NTEP.

Version 1.15

This parameter added in SERIAL menu under EDP port (EDP.ECHO=On/Off) to enable or disable

echoing of serial commands sent to indicator.

Version 1.16

This version corrects an issue introduced in Version 1.15 where the primary unit with a fixed zero was

divided by 10 when displaying secondary units.

Version 1.17

Added an OFF selection for secondary units to disable the secondary mode.

Added a selection in the Serial Menus for 1 or 2 Stop Bits.

Added the capability to use 3, 4, 5, 6, 9, 25, and 35 Display Divisions. Contact RLWS for details.

The IQ355 is now fully compatible with the IQ310A EDP command set

TEST Menu

Function

Description

A/DTST

Display A/D test
Press and hold Enter key to display raw count from A/D converter.

D/I 1

Display digital input 1

Press and hold Enter key to show status of DIGIN1 (DI1=HI or DI1=LO).

D/I 2

Display digital input 2

Press and hold Enter key to show status of DIGIN2 (DI2=HI or DI2=LO).

AOUT=0

Set analog output to zero

Press and hold Enter key to set analog output to its zero value.

AOUTFS

Set analog output to full scale

Press and hold Enter key to set analog output to its full scale value.

DEFLT

Default parameters

Press setup switch and Enter key at the same time to reset configuration and calibration parameters to factory
default values. Load cells must be recalibrated before using the indicator (see Section 4.0 on page 24).

XMT U

Transmit “U”

Press and hold Enter key to send ASCII “U” characters (decimal 85) from the serial port.

ECHO R

Echo received characters

Press and hold Enter key to view characters received at serial port.

NOTE:

IQ plus 355 display shows lower-case characters as blanks.

Table 7-7. Test Menu Functions

Advertising