Rice Lake IQ Plus 355 Installation Manual V1.17 User Manual

Page 37

Advertising
background image

EDP Commands

33

310 Command

355 Command

Description

AZ

KZERO

Sets scale to zero. Valid only in Operate Mode.

FT

KTARE

Performs a front panel tare operation. Entering “FT <EOL>” acquires a tare like pressing
the TARE key.

CT

Clear Tare

Tare out (removes the tare value)

LB

KPRIM

Selects “lb” for weight units (if set up for “lb” or “kg” units mode)

KG

KSEC

Selects “kg” for weight units (if set up for “lb” or Kg” units mode)

GN

KGROSSNET

Simulates a GROSS/NET key press. Entering “GN <EOL>” toggles between the gross
and net display mode.

PR

KPRINT

Sends formatted weight data to either or both serial ports.

RS

RS

Resets system.

SX

SX

Starts continuous serial transmission on the EDP port using the selected serial output
data format. Serial transmission stops in SETUP mode.

EX

EX

Ends continuous serial transmision on the EDP port.

XG

XG

Transmits GROSS [9 characters, leading zeros suppressed (spaces), decimal point if
applicable, minus sign to left of first active digit]. Valid only in Operate Mode.

XN

XN

Transmits NET [9 characters, leading zeros suppressed (spaces), decimal point if
applicable, minus sign to left fo first active digit]. Valid only in Operate Mode.

XT

XT

Transmits TARE [9 characters, leading zeros suppressed (spaces), decimal point if
applicable, minus sign to left fo first active digit]. Valid only in Operate Mode.

XD

P command

Transmits the value currently displayed.

XS

S command

Transmits a single serial string from the EDP port in the selected output format.

Table 5-12 IQ310A Commands

Advertising