Fixed gain, Exposure time, Fixed gain -12 – Rice Lake Motorola DS457 Laser Scanner User Manual
Page 106: Exposure time -12, Fixed gain parameter # f1h 38h, Exposure time parameter # f4h f1h 37h
7 - 12 DS457 Fixed Mount Imager Integration Guide
Fixed Gain
Parameter # F1h 38h
This parameter only applies when Decoding or Image Capture Autoexposure is disabled. Gain is a means of
amplifying the raw image data before it is converted into 8-bit grayscale values. Increasing the fixed gain
increases brightness and contrast, but also increases noise (undesired electrical fluctuations in the image)
which makes the image less attractive and/or harder to decode.
To set the fixed gain, scan the bar code below followed by 3 bar codes from
,
in the range of 1 to 100, representing the value. The default is 50.
Exposure Time
Parameter # F4h F1h 37h
This parameter only applies when Decoding or Image Capture Autoexposure is disabled. It configures the
exposure for both Decode and Snapshot modes.
Each integer value represents 100
μ
s
worth of exposure. The default value is 100 which results in an exposure
setting of 10 ms.
To set the Exposure Time parameter, scan
Fixed Exposure
followed by four numeric bar codes representing
the value in the range of 1 - 1000. Insert leading zeros if necessary. For example, to set a Fixed Exposure
value of
for numeric bar codes.
Fixed Gain
Exposure Time
(4 digits)