Ocr check digit modulus, Ocr check digit modulus -25, Ocr check digit modulus parameter # f1h b0h – Rice Lake Motorola DS457 Laser Scanner User Manual

Page 217

Advertising
background image

OCR Reading 11 - 25

Template Examples

Following are sample templates with descriptions of valid data for each definition.

Field Definition

Description

"M"99977

M

followed by three digits and two optional digits.

"X"997777"X"

X

followed by two digits, four optional digits, and an X.

9959775599

Two digits followed by any character, a digit, two optional digits, any two

characters, and two digits.

A55"-"999"-"99

A letter followed by two characters, a dash, three digits, a dash, and two digits.

33A"."99

Two alphanumeric characters followed by a letter, a period, and two digits.

999992991

Five digits followed by an optional alpha, two digits, and an optional alphanumeric.

"PN98"

Literal field -

PN98

OCR Check Digit Modulus

Parameter # F1h B0h

This option sets OCR module check digit calculation. The check digit is the last digit (in the rightmost position)

in an OCR string and improves the accuracy of the collected data. The check digit is the end product of a

calculation made on the incoming data. For check digit calculation, for example Modulus 10, alpha and

numeric characters are assigned numeric weights (see

OCR Check Digit Multiplier on page 11-26

). The

calculation is applied to the character weights and the resulting check digit is added to the end of the data. If

the incoming data does not match the check digit, the data is considered corrupt.

The selected check digit option does not take effect until you set

OCR Check Digit Validation

.

To choose the Check Digit Modulus, such as 10 for modulo 10, scan the following bar code, then scan a

three-digit number from 001 to 099 representing the check digit using the Numeric Keypad from the

Advanced

Data Formatting Programmer Guide

. The default is

1

.

OCR Check Digit

Advertising